Eppendorf 5402 Manual

Maintain at least 30 cm (12 inches) of open space on all sides. This clearance ensures proper ventilation for the cooling compressor and allows the unit to shift safely in the rare event of a rotor failure.

In the event of a power failure or mechanical lock engagement, the lid may be opened manually using the emergency release tool located in the rotor accessories kit. If tool is unavailable, use a 3mm Allen wrench inserted into the access port located at the rear-right side of the chassis.

Regular upkeep extends the lifespan of the refrigerated system and mechanical components. Routine Cleaning

For labs that still rely on the 5402, the manual is not just a reference—it’s a survival guide. Without it, ordering replacement rotors (like the discontinued 5402 350.008) is impossible. Without the imbalance calibration procedure, the machine will shut down after every run. eppendorf 5402 manual

Centrifuge 5420. Page 1. ating Instructions. 20EN)Operating Instructions. Register your instrument! www.eppendorf.com/myeppendorf. Eppendorf 5402 Refrigerated Centrifuge - G-M-I, Inc.

Balance tubes by mass, not just volume. Differences of more than 0.1 grams can cause vibrations at 14,000 rpm.

Do not allow tube caps or tabs to overlap, as this can interfere with the lid seal. Maintain at least 30 cm (12 inches) of

Never operate the centrifuge with an unbalanced load. If spinning one tube, use a "balance" tube of equal weight directly opposite it. Key Operating Procedures

Plug the unit directly into a grounded electrical outlet matching the voltage specified on the manufacturer’s ID plate (typically 120V or 230V). Avoid using extension cords. Critical Safety Rules Never override the lid-locking mechanism. Never move the centrifuge while the rotor is spinning.

Quick Guide: Operating the Eppendorf 5402 Refrigerated Microcentrifuge Overview: The Eppendorf 5402 Go to product viewer dialog for this item. If tool is unavailable, use a 3mm Allen

: Rotors can be damaged by aggressive chemicals like halogenated hydrocarbons or concentrated saline solutions; spills should be cleaned immediately with distilled water. Common Troubleshooting Codes

When the Eppendorf 5402 encounters an issue, it utilizes internal sensors to halt operation and protect your samples. Error Messages & Solutions Problem / Error Likely Cause Recommended Action Lid not closed completely, or power supply disconnected.

Check the power cord connection and inspect the rear fuse panel. Rotor is still spinning or power is off.